Online beermonitor
The Principle
The BEERMONITOR is a special type of COMBITEC sensor. Before fermentation there exists a
2-component system – a mixture of water and extract. The concentration of this liquid can be determined by measuring density or sound velocity. During fermentation the sugars in the wort are converted into alcohol and CO2. Thus, a 3-componnet system consisting of water, extract and alcohol emerges. By a combination of fluid density sensing and sound velocity measurement, alcohol and extract content can be separately determined. This allows calculating the degree of fermentation and the Original Gravity (OG) with extreme precision (“Balling’s Formula”). OG is a crucial factor for the alcohol content and the character of the finished beer and needs to be controlled with care. The increasing CO2 content is automatically compensated for by CO2measurement with CARBOTEC. OG can also be determined by just measuring sound velocity. During fermentation the sound velocity does virtually not change. As a special type of SONATEC, the PLATOMONITOR is an economic instrument for OG calculation without extract and alcohol measurement. However, compared to the BEERMONITOR its accuracy is slightly lower.
Characteristics
Available as Transmitter Version with Local Display and as Sensor
Highly Precise and Fast Determination of Alcohol, Extract and OG
Based on Density and Sound Velocity Measurement
Designed for the Specific Needs of Breweries
Short Response Time and Excellent Long-Term Stability
Hygienic Execution, Full CIP Capability and Maintenance Free
Outstanding Price-Performance-Ratio
Application
Determination of Alcohol and Extract During Fermentation
Specification
Technical Data | BEERMONITOR | PLATOMONITOR |
Original Gravity Measurement Range Accuracy |
0-25°Plato ±0,03°Plato |
0-25°Plato ±0,05°Plato |
Extract Measurement Range Accuracy |
0-10 mass% ±0,02mass% |
Not measured |
Alcohol Measurement Range Accuracy |
0-12,5 vol.% ±0,02vol.% |
Not measured |
Response Time | ≤1s | ≤1s |
Pressure of Operation | Max.16bar | Max.16bar |
Temperature of Operation | -25-+125℃ | -25-+125℃ |
Temperature Compensation | Pt1000 | Pt1000 |
Material
| 1.4404/AISI 316L Hastelloy C276; Monel 400; Incoloy 825; others on request | 1.4404/AISI 316L; Hastelloy C276; Monel 400; Incoloy 825;others on request |
Connections
| Compatible to Varivent© Inline-Housings DN40-DN150;others on request | Compatible to Varivent© Inline-Housings DN40-DN150;others on request |
Input Transmitter Version | 10×digital(24VDC)& 2×analog(4-20mA) | 6×digital(24VDC) |
Output Transmitter Version | 5×digital(24VDC)& 2×analog(4-20mA) | 3×digital(24VDC)& 2×analog(4-20mA) |
Profibus DP Transmitter Version Sensor(w/o local display) |
Option standard |
Option standard |
Enclosure Rating | IP65 | IP65 |
Power Supply | 24 VDC | 24VDC |