Online gas chromatograph
Gas chromatograph based on thermal conductivity detector (TCD) can analyze up to 16 gases
It includes hydrocarbons, CO2, N2, H2S, C2+~C9+, etc
Application
BTU calorific value analysis, specific gas component concentration, specific gravity, compression factor, whiting index, etc
Biogas
Standard C6+ ~ C7+ analysis;
Impurities of trace magnitude -- -h2s, CO, CO2, O2, etc
Conversion energy analysis from C6+ to C7+
C9+ analysis with hydrocarbon dew point;
Liquefied natural gas
C3 / C4 analysis
C2 ~ C5+ analysis
Acid gas
CO2 and H2S analysis of oil and gas well inlet;
Analysis of CO2 and H2S imported or exported from sulfur recovery unit;
Petrochemical
•acetylene (C2H2), ethylene (C2H4), ethane (C2H6), propylene (C3H6), propane (C3H8), hydrogen (H2)和 Carbon monoxide (CO);
Features
High precision analysis
For C6+, it is 1.0 BTU/1000
Accuracy: 0.1% full range
Flexible application
Measuring mixture of gases in a gas chromatograph
Wide dynamic range from % to trace magnitude
Configurable Modbus, storage, processing, alarm and other functional modules
Programmable mathematical or logical formulas
Friendly UI
Measurement and diagnosis based on ICE software of Windows system
Replaceable and repairable GC module (valve or column unit)
Optional Chromatographic workstations, industrial standard reports with output functions and reports
Chromatographic analysis spectra storage, browsing historical data, report printing at will
Low running and maintenance costs
No compressed air required
Heating furnaces with sampling systems do not require an external shield
Low helium and low power consumption
Specification
Power supply | 24 VDC @≤ 50W 或 100–240 VAC 50/60 HZ@≤ 50W |
Explosion-proof area | Class 1, Div1 Grps C & D (model131GC) Class 1, Div2 Grps C & D (model 132GC)
|
Operation temperature | -18 ~55˚C (standard),customizable |
Output range | from0–500 ppm to 0–100% (up to 16 gases) Contact the manufacturer for detail |
Response time | Measuring H2S only (2min) measuring H2S &CO2 (3min) Measuring C6+ calorific value using a single injection valve (10min) |
Precision | 0.1% full range |
Input | TCD temperature control sensor Four main connectors Up to 8 channels of gas |
Output | Dual isolation 4-20ma (requires loop power supply) 1 rs-232, 4 rs-485 4 5A single pole double throw alarm output relays 4 solid state solenoid drivers |
Display | Backlit 2x16 word LCD display Operation menu through built-in buttons and external magnetic keys; The menu includes gas concentration value, calorific value (BTUs or other units), specific gravity, wobbe index, compression factor, combustion efficiency; |
Carrier gas | Ultra high purity helium at 7~20cc/min at 50~150psi(345 ~1034 kPa) |
Weight | 131GC:30kg(65lbs) 132GC:18kg(40lbs) |
Storage | 24,000 data point ;settable frequency and dimension |
Dimension | 131GC:95.3cmHx53.4cmWx25.4cmD(37.5"Hx21"Wx10"D) 132GC:81.3cmHx48.3cmWx19cmD(32"Hx19"Wx7.5"D) |
Calibration | Calibration via software timing or external switches |