Portable Dissolved Ozone Analyzer OXYTRANS M Portable Version
The Principle
OXYTRANS continuously measures the content of oxygen in liquids and gases. Designed for applications that require maximum sensitivity and high accuracy, this device is used in various industries all around the world. Breweries and soft drink manufacturers determine the O2 content in deaerated water and beverages with OXYTRANS. Oxygen measurement during fermentation is an ideal application. Numerous power plants use the sensor to monitor oxygen levels in their boiler water. The state of the art optical measurement technology is based on the effect of luminescence quenching, i.e. the radiationless redistribution of excitation energy via a molecular interaction. An indicator layer on a small glass component (“optical window”) installed in the measuring head is illuminated with blue-green-light. When the indicator molecules absorb the incident light they are promoted to a higher energy state. After a certain time they convert back to their ground state during which a detectable red light is emitted. If O2 is present the energy is transferred from the indicator molecules to the oxygen. The detected signal decreases according to the oxygen content. OXYTRANS displays various units, e.g. ppb, ppm and % oxygen. The lightweight portable device is very robust and can easily be connected with hoses.
Characteristic
· Available as Transmitter and Portable Version with Local Display
· Highly Precise and Fast Measurement of O2 in Liquids and Gases
· Optical Technology without Membrane and Electrolyte
· Short Response Time and Excellent Long-Term Stability
· Hygienic Execution and Full CIP Capability
· Easy Maintainable within a Few Minutes
· Outstanding Price-Performance-Ratio
Technical Data
OXYTRANS TR OXYTRANS M
Liquid Phase I) 0.1 ppb - 2 ppm or I) 0.1 ppb - 2 ppm or
Measuring Range II) 30 ppb - 50 ppm II) 30 ppb - 50 ppm
Liquid Phase Accuracy I) ± 0.1 ppb or I) ± 0.1 ppb or
II) ± 30 ppb II) ± 30 ppb
Gas Phase I) 0 - 4,2 % O2 or I) 0 - 4,2 % O2 or
Measuring Range II) 0 - 50 % O2 II) 0 - 50 % O2
Gas Phase Accuracy I) ± 0,002 % O2 I) ± 0,002 % O2
II) ± 0,03 % O2 II) ± 0,03 % O2
Response Time t90 ≤ 10 s t90 ≤ 10 s
Pressure of Operation max. 12 bar max. 12 bar
Temperature of Operation - 5 - + 55 °C (option: + 98 °C) - 5 - + 55 °C (option: + 98 °C)
resistance: max. + 130 °C resistance: max. + 130 °C
Temperature Compensation Pt100 Pt100
Material 1.4404/AISI 316L, 1.4404/AISI 316L,
silicone (FDA), PTFE (FDA) silicone (FDA), PTFE (FDA)
Connections Compatible to Varivent© Hoses of 6 mm diameter
Inline-Housings DN40 - DN150;
DIN; ANSI; others on request
Interface (OXYTRANS TR) input: 3 x digital (24 VDC) manual and automatic with a logging time of
output: 3 x digital (24 VDC) & 5 to 600 seconds; approx. 5.000 measurement
Datalogging (OXYTRANS M) 2 x analog (4 - 20 mA) values; PC software and USB-interface
Profibus DP option -
Enclosure Rating IP65 IP65
Power Supply 24 VDC battery, rechargeable
Weight - 1,65 kg